| Product
Description> Attemper and Reducer Device
Catalog of High Temperature and Pressure
Device of Second Generation
£¨I£©Purpose
This device reduces pressure P1 and temperature
t1 of new steam £¨P1¡Ü10MPa£¬t1¡Ü540¡æ£©to requirements of different pressure
P2 and temperature t2 needed by customers.
£¨II£©Brief Introduction of Structure
This device consists of reducer system, attemper
system, safety protection device and automatic control device.
Reducer system¡ª¡ªmade up of reducer valve
and throttle plate, realizing through executive framework.
Attemper system¡ª¡ªadopt water spray temperature
reducing manner inside blending pipeline. It uses active force of
cooling water towards spray nozzle and bounce of the spring to adjust
flow area of cooling water of the nozzle and realizes adjustment
of steam temperature through the opening of water control valve
controlled by executive framework.
Safety protection device¡ª¡ªadopt impulse
safety device£¨consisting of safety valve and impulse safety valve£©or
spring safety valve to realize. When secondary pressure surpasses
regulated value, it gives out steam of surpassing part of pressure
into the air and thus keeping secondary pressure within allowed
value.
Automatic control device¡ª¡ªassemble RKG¡ª¡õ¡õ¡õ¡õ
model steam pressure and temperature control device produced by
our plant. Passing this device, new steam can maintain parameters
of second steaming at stable value needed.
£¨III£©Performance Indices
1.Inlet steam pressure P1¡Ü 10MPa and temperature t1¡Ü540¡æ£»
2.Outlet flow Q£ºchanging range of outlet flow Q of attemper and
reducer is 10%¡«100%, within range it can realize ideal adjustment.
3.Changing range of outlet steam pressure P2 is£º
When P2¡Ü0.98MPa, changing range of P2 is P2¡À0.4MPa£»
When 0.98£¼P2¡Ü3.82MPa, changing range of P2 is P2¡À0.06MPa£»
And when P2£¾3.82MPa, changing range of P2 is P2¡À0.15MPa.
4.Adjustment range of outlet steam temperature t2 is t2¡À4¡æ.
5.In course of normal running, at 1 meter of lower end of attemper
and reducer valve, and also 1 meter away from pipe wall, noise grade
is not more than 85db.
£¨IV£©Supply Range
Supply range of high-temperature and
pressure attemper and reducer device is within
mark, mainly are£º
1.Reducer system£ºattemper and reducer valve, and throttle plate
etc£»
2.Attemper system£ºwater control valve, umbrella-shape automatic
adjustable nozzle inside the blending pipeline and throttle valve
etc£»
3.Safety system£ºsafety valve and check valve etc£»
4.Pipeline sytem£ºsteam pipeline, transition pipe and attemper water
pipe and blending pipeline etc£»
5.Matched fittings£ºstop valve, double-metal thermometer and take-over,
pressure meter and three-way pipe, syphon, adapter, flange, cushion,
bolt, nut and gasket etc.
GWY-01 Model High-temperature and Pressure Reducing Device Series
Chief Chart£¨A Set of Impulse Safety Valve PN4/PN10£©
>Previous¡¡>Next
|